An original Ender 3 uses about 125 W while printing PLA, or 0.125 kWh an hour, which costs 2.2 cents at the US average price of $0.179 per kWh. Later models measure lower: about 110 W for the V2 and 80 W for the S1. The rated maximum is 270 W on the original and 350 W on the V2 and every model since.
How much power does an Ender 3 use?
An original Ender 3 averages about 125 W while printing PLA at 200 °C with a 60 °C bed, and peaks near 277 W while heating up. Published measurements put the Ender 3 V2 at 110 W and the Ender 3 S1 at about 80 W. An hour of printing uses 0.08 to 0.125 kWh.
| Model | Rated power | Power supply | Heated bed (24 V, 235 × 235 mm) | Measured average, PLA |
|---|---|---|---|---|
| Ender 3 | 270 W | 24 V, 270 W | 220 W | 125 W |
| Ender 3 V2 | 350 W | 24 V Mean Well | 220 W | 110 W |
| Ender 3 S1 | 350 W | 24 V Creality CMS-350-24 | 270 W | about 80 W |
| Ender 3 V3 SE | 350 W | not named | 270 W | not published |
| Ender 3 V3 KE | 350 W | not named | 270 W | not published |
Each measured figure comes from one tester’s plug-in meter, not from Creality. 3DSolved logged the original Ender 3 with an electricity usage monitor. Furkan Ermanas Yabancı measured a V2 with a smart socket at a 200 °C nozzle, a 60 °C bed and 25 °C room temperature. 3DPrintBeginner read the S1’s draw from a Blitzwolf smart socket.
Your own room temperature, bed setting and print will move the average.
What is the Ender 3 wattage?
The rated wattage is 270 W for the original Ender 3 and 350 W for the V2, S1, V3 SE and V3 KE. That rating is the most the supply can deliver, not what the meter bills. Real peaks sit below it: 277 W on the original Ender 3 and about 290 W on the S1, both while the bed and hotend heat together.
At 120 V, 270 W is 2.25 A and 350 W is 2.9 A.
A print longer than 3 hours is a continuous load under the National Electrical Code (NEC), so it may use only 80 percent of the breaker: 12 A on a 15 A circuit. One 350 W Ender 3 uses 24 percent of that. Four of them reach 11.7 A, right at the limit. The circuit capacity calculator adds up everything else on the same breaker.
Idle draw is small. 3DPrintBeginner measured the S1 at about 8 W switched on and idle.
How much power does the Ender 3 heated bed use?
The original Ender 3 and the V2 use a 220 W, 24 V bed. The S1, V3 SE and V3 KE use a 270 W, 24 V bed. Both are 235 × 235 mm. The bed is 77 to 81 percent of each printer’s rated power, which is why it sets both the peak and the bill.
Once at temperature the bed cycles on and off. 3DSolved measured the original Ender 3’s bed at 80 W on average at 60 °C and up to 260 W while heating. That is 64 percent of the printer’s 125 W average. The hotend averaged about 30 W, and the motors and board took the remaining 15 W.
Heat-up takes minutes, not hours:
- Ender 3: the bed reaches 110 °C in about 5 minutes, according to Creality.
- Ender 3 S1: 60 °C in 2 minutes 5 seconds and 100 °C in 6 minutes 15 seconds, as 3DPrintBeginner timed it.
Five minutes at the 277 W peak uses 0.023 kWh, under half a cent. Because the bed takes most of the steady draw, its temperature setting is the biggest lever on the bill. To size a replacement supply for a bigger bed, use the power supply calculator.
How much does it cost to run an Ender 3?
Multiply the average watts by the hours and divide by 1,000 for kWh, then multiply by your price per kWh:
kWh = average watts × hours ÷ 1000
cost = kWh × price per kWh
4-hour PLA print, original Ender 3: 125 W × 4 h ÷ 1000 = 0.50 kWh → 0.50 × $0.179 = $0.090
| Model | Average | kWh per hour | Cost per hour | 4-hour PLA print |
|---|---|---|---|---|
| Ender 3 | 125 W | 0.125 | $0.022 | 0.50 kWh, $0.090 |
| Ender 3 V2 | 110 W | 0.110 | $0.020 | 0.44 kWh, $0.079 |
| Ender 3 S1 | 80 W | 0.080 | $0.014 | 0.32 kWh, $0.057 |
| Any 350 W model at full rating | 350 W | 0.350 | $0.063 | 1.40 kWh, $0.25 |
A 4-hour PLA print costs 6 to 9 cents. The last row is a ceiling no Ender 3 reaches over a whole print. The price is the U.S. Energy Information Administration’s residential average for the 12 months ending June 2026. The electricity cost calculator reruns this with the rate on your own bill or a smart plug reading.
How much power does the Ender 3 V3 SE use?
Creality rates the Ender 3 V3 SE at 350 W on 100 to 120 V or 200 to 240 V AC, with a 270 W, 24 V bed. No measured average has been published for it, or for the V3 KE. The S1 has the same 350 W rating and the same 270 W bed, and it measured about 80 W on PLA. Plan on 80 to 125 W, or 1.4 to 2.2 cents an hour, until a smart plug gives you your own figure.
Published · Figures last checked
Sources
- MatterHackers, Creality3D Ender 3 3D printer kit (technical specifications) (accessed 2026-10-10)
- Creality, Ender-3 V2 3D printer user manual (equipment parameters) (accessed 2026-10-10)
- Creality official store, Ender-3 V2 3D printer (archived December 2022, Mean Well power supply) (accessed 2026-10-10)
- MatterHackers, Creality3D Ender 3 S1 3D printer kit (specifications) (accessed 2026-10-10)
- Creality, Ender-3 V3 SE support: specs (rated power and voltage) (accessed 2026-10-10)
- Creality, Ender-3 V3 KE support: specs (rated power and voltage) (accessed 2026-10-10)
- 3DSolved, Facundo Arceo, Ender 3 power consumption (3D printer electricity usage) (accessed 2026-10-10)
- Furkan Ermanas Yabancı, Power consumption of the Creality Ender-3 V2 (Medium) (accessed 2026-10-10)
- 3DPrintBeginner, Creality Ender 3 S1 review (power draw and heating times) (accessed 2026-10-10)
- 3D Printing Canada, Official Creality Ender 3 heat bed (24 V, 220 W, 235 x 235 x 3 mm) (accessed 2026-10-10)
- Spool3D, Creality Ender 3 S1 heat bed (24 V, 270 W) (accessed 2026-10-10)
- Spool3D, Creality Ender 3 V3 SE heated bed kit (24 V DC, 270 W, fits V3 SE and V3 KE) (accessed 2026-10-10)
- Creality official store, Ender 3 3D printer (archived December 2022, hotbed to 110 °C in 5 minutes) (accessed 2026-10-10)
- U.S. Energy Information Administration, Electric Power Monthly Table 5.3: Average Price of Electricity to Ultimate Customers (accessed 2026-10-10)
- IAEI Magazine, Thomas A. Domitrovich, 100% vs 80%: choosing the right OCPD solution (quotes NEC Article 100 and 210.20(A)) (accessed 2026-10-10)